Sherwin D-100 Developer

D-100 developer consists of refined white particles suspended in isopropyl alcohol.

Available in:

  • 300ml Aerosol (12 pack)
  • 500ml Aerosol (12 pack)

Description

Giving enhanced sensitivity for locating tight, incipient flaws. Extremely white layer and tense aspect. Extended and optimized granulometry.

 

Sherwin D-100 Developer: Precision in Penetrant Inspection

Unleash the power of Sherwin D-100 Developer to elevate your penetrant inspections to new heights. Designed to enhance sensitivity and flaw detection, D-100 employs refined white particles suspended in isopropyl alcohol. This winning combination facilitates flaw-entrapped penetrant migration to the part surface, presenting them vividly against a white backdrop. D-100 offers superior performance and complies with low sulfur and low halogen requirements.

 

Key Features:

  • Enhanced Sensitivity: D-100 creates a thinner, more uniform, and highly absorbent coating, boosting sensitivity to tight flaws.
  • Superior Suspension: Enjoy excellent suspension properties that ensure flaw-entrapped penetrant is showcased effectively.
  • Versatile Application: D-100 works effortlessly on smooth and rough surfaces, making it suitable for various applications.
  • Easy Removal: Light brushing or a simple spray water rinse is all it takes to remove excess D-100, saving time and effort.
  • Compatibility: D-100 is compatible with visible and fluorescent penetrants, offering flexibility in your inspection processes.

Specifications:

  • Complies with SAE AMS 2644 & QPL – Form D & E, MIL-I-25135 Revisions C, D, & E, ASME Code NDT, Sec V, and various industry standards.
  • It is trusted by industry leaders like Lockheed Martin, Boeing, Rolls Royce, Honeywell, Pratt & Whitney, Airbus, General Electric, and Northrup Grumman.

Instructions for Use:

  1. Application: Apply penetrant to clean, dry surfaces through spraying, flowing, brushing, or dipping.
  2. Dwell Time: The suggested dwell time is 10 minutes, with the flexibility to extend for tight cracks or critical parts.
  3. Removal: Use the appropriate washing method to remove excess penetrant.
  4. Drying: A re-circulating oven (not exceeding 160°F) is recommended for efficient drying.
  5. Developing: Evenly spray a light coating of D-100 onto the dry surface after agitating the suspension.
  6. Inspection: Conduct inspections under suitable light-intensity conditions.

Safety Considerations:

  • D-100 is highly flammable, so use it in well-ventilated areas.
  • Avoid prolonged inhalation of vapour and skin contact; do not ingest.
  • Refer to the MSDS for comprehensive safety and health information.

Trust Sherwin D-100 Developer for precise and reliable penetrant inspections. Elevate your flaw detection capabilities with this industry-proven solution.