TAM / PSM 5 Panels
SPECIAL USAGE
CONSIDERATIONS
-
Use a separate set of PSM-5TM
Panels for each penetrant system. Do not use penetrants with
different sensitivity levels on the same set of panels.
-
PSM-5TM Panels should be
recalibrated periodically. One major company, which mandates the use
of PSM-5TM Panels, based on their experience, requires
the calibration of their own, in-house panels approximately every
six months. Experience has shown that recalibration requirements
will vary with how much a panel is used and with how well it is
maintained Sherwin Incorporated recommends that PSM-5TM
Panels be recalibrated, at least, annually.
Panels may be returned to the factory for
cleaning, re-git blasting, crack measurement and recertification. Obtain
quotes from Sherwin Incorporated.
-
PSM-5TM Panels should be
protected from scratches, thermal cracking, over-rubbing of grit
blasted surface and exposure to corrosive materials.
-
With usage, there is a tendency for
the smallest cracks to clog with residue and for the grit blasted
area to lose its roughness. Please refer to the maintenance section.