SPECIFIC USE PROCEDURES
-
A PSM-5TM Panel must be
clean and completely dry before use. Follow the procedures described
in the maintenance section.
-
Place the PSM-5TM Panel
near the center of the parts basket in as near an upright position
as possible; it should not lie flat. Typically, the panel is
processed with the “E” or largest crack center in the top position.
The panel should be positioned the same way every time a test is
conducted.
-
Process the PSM-5TM Panel
at the beginning of each shift. Record all processing variables in a
log. The panel may be processed alone or with other PARTS. If it is
processed with other parts, insure that the other parts do not
damage the panel. Also, if the panel is processed with other parts
which must be pre-cleaned, do not pre-clean the panel if there is
danger to the panel of thermal shock.
-
Follow normal production procedures.
If processing manually, the suggestion is to use parameters most
adverse to system performance, such as…
a.
…minimum allowable penetrant
dwell time.
b.
…maximum allowable wash,
emulsifier immersion and drain times.
c.
…maximum anticipated wash
pressure and temperature.
d.
…maximum anticipated oven
temperature and exposure time.
e.
…minimum allowable
developing time.
-
Handle the PSM-5TM Panel
with reasonable care to avoid scratches, thermal shock, or other
damage.
-
Clean the PSM-5TM Panel
immediately after use. See the maintenance section for cleaning
procedures. Be sure the panel is completely clean and dry before
each use.