  1. A PSM-5TM Panel must be clean and completely dry before use. Follow the procedures described in the maintenance section.

  2. Place the PSM-5TM Panel near the center of the parts basket in as near an upright position as possible; it should not lie flat. Typically, the panel is processed with the “E” or largest crack center in the top position. The panel should be positioned the same way every time a test is conducted.

  3. Process the PSM-5TM Panel at the beginning of each shift. Record all processing variables in a log. The panel may be processed alone or with other PARTS. If it is processed with other parts, insure that the other parts do not damage the panel. Also, if the panel is processed with other parts which must be pre-cleaned, do not pre-clean the panel if there is danger to the panel of thermal shock.

  4. Follow normal production procedures. If processing manually, the suggestion is to use parameters most adverse to system performance, such as…

a.                   …minimum allowable penetrant dwell time.

b.                  …maximum allowable wash, emulsifier immersion and drain times.

c.                   …maximum anticipated wash pressure and temperature.

d.                  …maximum anticipated oven temperature and exposure time.

e.                   …minimum allowable developing time.

  1. Handle the PSM-5TM Panel with reasonable care to avoid scratches, thermal shock, or other damage.

  2. Clean the PSM-5TM Panel immediately after use. See the maintenance section for cleaning procedures. Be sure the panel is completely clean and dry before each use.

 