HM-406 - FLUORESCENT PENETRANT
 
MANUFACTURER
: SHERWIN (USA)/NDT Europa (NL)
DISTRIBUTOR: NDT Consultants
Limited (UK)
DESCRIPTION / APPLICATIONS:
Level 2 water washable fluorescent penetrant designed for detecting
surface defects.
COMPANION PRODUCTS:
DR 60, DR 62 removers
N 120 degreaser / N 106 A,
D 100, D90G developer
R 62 quick-drying developer
SPECIFICATIONS / STANDARDS:
SAE-AMS 2644-QPL 2644-1 approved
Type I Method A level II,
GENERAL ELECTRIC: A, B, C, D
PRATT and WHITNEY: highly sensitive FPM (code 2)
ALLISON: level 2
MTU: 83/298
BOEING, LOCKHEED: in accordance with QPL
MTU MUNCHEN
AIRBUS-EADS
PHYSICO-CHEMICAL PROPERTIES:
Aspect: green liquid
Fluorescence: green-yellow
Flash point: > 93° C.
Viscosity: 5.2 mm²/s ± 10% at 38°C
Water tolerance: 5 %
Very low halogen and sulfur content
Compatible with all metals and certain plastics.
Density: 0.88 ± 10%
PACKAGING / SHIPPING / STORAGE:
Packaging: 1-, 5-, 10-liter canisters
60-liter drum / 200-liter drum
Shipping / Handling: refer to MSDS
Storage / Shelflife: keep away from moisture
Temperature limit: 0 to 50°C. (32° to 120°F)
Keep the packaging closed after taking out some of the product
Canister/Drum: 48 months
INSTRUCTIONS:
(These describe the basic process, but they may need to be amended by
the user to comply with applicable specifications and/or inspection
criteria provided by the contracting agency).
1. Application: Apply HM-406 only to clean, dry surfaces by
spraying, flowing, brushing or dipping.
2. Dwell-Time: A 10 minute dwell time is suggested, although in
many cases five minutes will suffice. When particularly tight cracks are
suspected, or the part is especially critical, the dwell time may be
extended to 30 minutes, or longer. Do not soak the part. To increase
sensitivity, as well as conserve material, allow the penetrant to drain
from the part surface back into the penetrant tank.
3. Removal: Use a quick, ambient temperature water wash at tap
pressure to rinse HM-406 from the part surface. To avoid washing
entrapped penetrant from surface flaws, do not use high water pressures
and temperatures, or prolonged washing and scrubbing.
4. Drying: A recirculating oven set no higher than 160°F (71°C)
is suggested. Leave part in oven just long enough to evaporate surface
moisture. Drying is improved by using pressurized air to disperse and
remove as much excess water as possible before placing part in oven.
5. Developing: HM-406 is self developing. Nevertheless it is
recommended to use a developer as listed above.
6. Inspection: Inspect parts under appropriate UV-A radiation and
dimmed visible light, in accordance with ISO 3059-2001 standard.
HEALTH AND SAFETY: refer to MSDS.
The information given herein is given in good faith to our customers
for the sole purpose of assisting them in the use of the products. The
document contains no formal or implicit guarantee regarding its use. NDT
Consultants Limited cannot be held responsible for damages of any nature
resulting from information provided in this document. In addition, none
of the information which the document contains should be interpreted as
a recommendation for the use of the products which would infringe the
protected rights of industrial property.
Download HM-406 Technical Data Sheet
Technical Support
Order Online
For any questions or queries
regarding this product please
contact
us!
Penetrant Testing Products
|