THIXOTROPIC FLUORESCENT PENETRANT - HM-3A 1THIXO


MANUFACTURER:
BABB CO
DESCRIPTION/APPLICATIONS:
Thixotropic
fluorescent penetrant (Level 2) for surface evenness test or fluorescent
penetrant testing.
COMPANION PRODUCTS :
Surface evenness test
Degreaser: N 120, cleaning rags N 120.
Removers: N 106A, cleaning rags N 106A.
Using any other means may “destabilize” HM 3A 1 THIXO,
i.e. may make it liquid.
Penetrant testing
Degreaser: N 120, cleaning rags N 120.
Removers: N 106A, cleaning rags N 106A.
Developers:
Dry powder: D 90G
Non aqueous wet developer: D 100, R60, R62.
SPECIFICATIONS / STANDARDS:
HM 3A by itself is
listed in many specifications.
HM 3A 1THIXO is
considered as a special application product.
HM 3A 1THIXO
approved by EDF (French Electricity Board) as PMUC (Products and
Equipments allowed for use in Nuclear Plants).
DATA:
- Appearance:
gel-like
- Fluorescence:
green-yellow
- Flash
point: > + 93°C (200 °F)
- Viscosity:
Very high, but highly lowered when stirred.
- Very
low halogens and sulphur content.
- Compatible
with any metal and ceramics, and some synthetic materials.
PACKAGING/TRANSPORT/STORAGE:
Packaging: 100 mL, 500 mL, 2,5 L cans.
Transport/ Handling:
refer to product MSDS (material safety
data sheet
Storage / Shelf life: Keep between 0°C
and 40°C, cans tightly closed;
Shelf life: >30 months.
INSTRUCTIONS:
Penetrant Testing
Thoroughly degrease surface with cleaning rags N 120
(recommended) or with clean rags moistened with N 120. Use a brush, a
rag, any convenient means to apply penetrant on the surface to be
checked.
Penetration time:
at least 20 to 30 minutes.
Excess penetrant
removal:
under adequate UV-A lighting. Remove most of the penetrant with clean,
dry rags. To complete removal use cleaning rags N 106A.
Allow 3 to 5 minutes for drying.
Developer:
follow respective technical data sheet.
Inspection:
visible light in inspection area shall be
less than 20 lux, UV-A irradiance at least 10 W/m˛ (if possible at least
15 W/m˛). When possible, conditions stated in ISO 3059 (Dec. 2001)
should be met.
Surface evenness testing
Vanes, flap valves
tightness.
All surfaces which come
in contact with each other shall be first degreased (with cleaning rags
N 120 preferably, or cleaning rags N 106A) then allowed for drying.
Be sure no fluorescent
indication (coming from white rags for instance) is visible.
Apply a very
thin coat of HM 3A 1THIXO, with a rag for instance, on the mobile part
of the equipment. Using UV-A light, check all the surface to be
checked is covered.
Put mobile part and non
mobile part in contact for some seconds. Do not allow any rotation.
Pull back mobile part. HM 3A 1THIXO lets a
fluorescent mark on the surface of the stationary part which came in
contact with the mobile part's.
Check for any mark
missing using UV-A lighting (15W/m˛ minimum, low visible light level).
Final cleaning may be
carried out using cleaning rags N 120, cleaning rags N 106A, or water if
allowed.
HEALTH AND SAFETY :
refer to MSDS.
The information
given herein is given in good faith to our customers for the sole
purpose of assisting them in the use of the products. The document
contains no formal or implicit guarantee regarding its use.
Babb Co cannot be
held responsible for damages of any nature resulting from information
provided in this document. In addition, none of the information which
the document contains should be interpreted as a recommendation for the
use of the products which would infringe the protected rights of
industrial property.